horizontal 3 ton coal fired steam boiler

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :horizontal 3 ton coal fired steam boiler
  • Supply Capacity : 10 units/month :horizontal 3 ton coal fired steam boiler
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

Get display discount

Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • (PPT) PIPE 1 COACHING NOTES 150 | pauline agustin

    The feed water enters the economizer at 145oC and leaves at 205oC. The steam leaves the boiler drum with a quality of 98%. The unit consumes 3 kg of coal per second as received having value of 25,102kJ/kg. What would be the overall efficiency of the unit in percent? Steam properties~ A. 65.72 B. 80.67 C. 88.28 D. 78.82 70.Get Price

  • (PDF) Report on "Steam Power Plant" | Saddam Hussain Sohag

    Steam condensing system consists of the following: (a) Condenser (b) Cooling water (c) Cooling tower (d) Hot well (e) Condenser cooling water pump (f) Condensate air extraction pump (g) Air extraction pump (h) Boiler feed pump (i) Make up water pump. 3.1.2 Steam production: Boiler is an apparatus to produce steam.Get Price

  • How to Calculate Gas Consumption in a Gas Boiler Burner?

    Mar 20, 2019 · We have over 70 years' experience of industrial steam boiler and autoclave, and we have a professional installation and after-sales staff for products.Take advantage of the most economical way to improve efficiency and operating flexibility, Get substantial savings on your fuel costs,Reduce all emissions for each K/W of electricity generated Get Price

  • Babcock and Wilcox boiler: Parts, Working, Advantages

    This is a water tube boiler, used in steam power plants. In this type of boiler, water is circulated inside the tubes and hot gases flow over the tubes. This is a Horizontal drum axis, natural draft, natural circulation, multitubular, stationary, high pressure, …Get Price

  • Refinery Terminology | refinery4refiners

    Apr 28, 2013 · Boiler which is used to produce steam (usually High Pressure Steam) by utilizing heat from reactor/fired heater flue gas, such as flue gas from Steam Reformer (in Hydrogen Plant), or acid gas from Reaction Furnace (in Sulphur Recovery Unit), or flue gas from fired heater/furnace (in other refinery processing units).Get Price

  • Economics | PDF | Heat Transfer - Scribd

    The steam leaves the boiler drum with a quality of 98%. The unit consumes 3 kg of coal per second as received having a heating value of 25,102 KJ/kg. What would be the overall efficiency of the unit in percent? Steam properties: At 5 Mpa and 400 oC : h = 3195.7 KJ/kg At 5 Mpa: hf = 1154.23, hfg = 1640.1 Ata. 65.Get Price

  • Satisfactory coal generator setup with water

    The coal is required for converting the feed water into the steam in the boiler. This setup has all 3 water extractors under-clocked to 75% each. 1×. 41. 4. The present study investigates the impact of various factors affecting coal-fired power plant economics of 210 MW subcritical unit situated in north India for electricity generation.Get Price

  • Babcock and Wilcox boiler: Parts, Working, Advantages

    This is a water tube boiler, used in steam power plants. In this type of boiler, water is circulated inside the tubes and hot gases flow over the tubes. This is a Horizontal drum axis, natural draft, natural circulation, multitubular, stationary, high pressure, …Get Price

  • Refinery Terminology | refinery4refiners

    Apr 28, 2013 · Boiler which is used to produce steam (usually High Pressure Steam) by utilizing heat from reactor/fired heater flue gas, such as flue gas from Steam Reformer (in Hydrogen Plant), or acid gas from Reaction Furnace (in Sulphur Recovery Unit), or flue gas from fired heater/furnace (in other refinery processing units).Get Price

  • Selective Catalytic Reduction

    High-dust arrangement (HD): The SCR unit is positioned immediately after the boiler. This configuration is used mostly in coal-fired applications, because the gas flue temperature at this location (300 - 400°C) is optimal for the catalyst activity. Dust removal is typically accomplished in cold electrostatic precipitators downstream of the SCR Get Price

  • How to Calculate Gas Consumption in a Gas Boiler Burner?

    Mar 20, 2019 · We have over 70 years' experience of industrial steam boiler and autoclave, and we have a professional installation and after-sales staff for products.Take advantage of the most economical way to improve efficiency and operating flexibility, Get substantial savings on your fuel costs,Reduce all emissions for each K/W of electricity generated Get Price

  • Economics | PDF | Heat Transfer - Scribd

    The steam leaves the boiler drum with a quality of 98%. The unit consumes 3 kg of coal per second as received having a heating value of 25,102 KJ/kg. What would be the overall efficiency of the unit in percent? Steam properties: At 5 Mpa and 400 oC : h = 3195.7 KJ/kg At 5 Mpa: hf = 1154.23, hfg = 1640.1 Ata. 65.Get Price

  • Compre Special Project (ppe &ipe) [vnd5gjm03rlx]

    ME Board Problem Local coal with higher heating value of 5,500 kCal/kg is burned in a pulverized coal fired boiler with 25% excess air at the rate of 25.9 M.T. per hour when the steam generated is 220 M.T. per hour. This boiler is served by 2 forced-draft fans of equal capacity delivering the air at 305 mm of water to the furnace.Get Price

  • Steam locomotive - Wikipedia

    A steam locomotive is a rail vehicle that provides the force to move itself and other vehicles by means of the expansion of steam.: 80 It is fuelled by burning combustible material (usually coal, oil or – now rare – wood) to heat water in the locomotive's boiler to the point when it becomes gaseous and its volume increases 1,700 times. . Functionally, it is a steam engiGet Price

  • Engineering Handbook For Hazardous Waste Incineration

    The vertical gas velocity is 3.5 m/s in the afterburner chamber at a thermal load of 25 Gcal/h. The off-gas at a rate of 66,000 Nm3/h leaves the afterburner chamber at a temperature of 1000°C. Heat is recovered in a steam boiler. The gases leave the boiler at 270°C. Steam is generated at 25 atm and superheated to 250°C at a rate of 34 t/h.Get Price

  • Satisfactory coal generator setup with water

    The coal is required for converting the feed water into the steam in the boiler. This setup has all 3 water extractors under-clocked to 75% each. 1×. 41. 4. The present study investigates the impact of various factors affecting coal-fired power plant economics of 210 MW subcritical unit situated in north India for electricity generation.Get Price

  • Railway Preservation News • View topic - How much can one

    Dec 07, 2021 · Several posts in this thread mentioned that an engine with a small boiler might not be able to meet steam demand going uphill, and would have to work on stored steam. While I grant you this is true, I must qualify that by saying "true of coal burners". The harder you work an oil burner, the better they steam.Get Price

  • Utility systems - processdesign

    Jan 13, 2014 · Figure 3.1 is a gas-turbine cogeneration process with a heat recovery steam generator (waste-heat) boiler. Gas-Turbine Cogeneration with a heat recovery steam generator boiler (Towler 2012 Fig 3.1) Overall, the process illustrated is not much different from a …Get Price

  • Engineering Thermodynamics: Problems and Solutions, Chapter-4

    A coal-fired boiler produces superheated steam steadily at 1 MPa, 4.943 ton/h, (b) 32.19 MW : Air is heated in a duct as it flows over resistance wires. Consider a 20 kW electric heating system. Steam enters a long, horizontal pipe with an inlet diameter of 14 cm at 1 MPa, 250 o C and a velocity of 1.2 m/s.Get Price

  • Steam locomotive - Wikipedia

    A steam locomotive is a rail vehicle that provides the force to move itself and other vehicles by means of the expansion of steam.: 80 It is fuelled by burning combustible material (usually coal, oil or – now rare – wood) to heat water in the locomotive's boiler to the point when it becomes gaseous and its volume increases 1,700 times. . Functionally, it is a steam engiGet Price

  • Home Central Furnaces for sale | eBay

    Steam. Corded Electric. Propane Liquid. Coal. Geothermal. Battery. Honeywell R8182D 1111 Horizontal Mount Boiler Control Triple Aquastat Relay. $282.00. (3) 3 product ratings - Legend Wood Boiler Laminated Solenoid - Models post 2009 Direct Replacement 002. $27.99. Free shipping. 215 sold.Get Price

  • Engineering Thermodynamics: Problems and Solutions, Chapter-4

    A coal-fired boiler produces superheated steam steadily at 1 MPa, 4.943 ton/h, (b) 32.19 MW : Air is heated in a duct as it flows over resistance wires. Consider a 20 kW electric heating system. Steam enters a long, horizontal pipe with an inlet diameter of 14 cm at 1 MPa, 250 o C and a velocity of 1.2 m/s.Get Price

  • (PPT) PIPE 1 COACHING NOTES 150 | pauline agustin

    The feed water enters the economizer at 145oC and leaves at 205oC. The steam leaves the boiler drum with a quality of 98%. The unit consumes 3 kg of coal per second as received having value of 25,102kJ/kg. What would be the overall efficiency of the unit in percent? Steam properties~ A. 65.72 B. 80.67 C. 88.28 D. 78.82 70.Get Price

  • Home Central Furnaces for sale | eBay

    Steam. Corded Electric. Propane Liquid. Coal. Geothermal. Battery. Honeywell R8182D 1111 Horizontal Mount Boiler Control Triple Aquastat Relay. $282.00. (3) 3 product ratings - Legend Wood Boiler Laminated Solenoid - Models post 2009 Direct Replacement 002. $27.99. Free shipping. 215 sold.Get Price

  • Utility systems - processdesign

    Jan 13, 2014 · Figure 3.1 is a gas-turbine cogeneration process with a heat recovery steam generator (waste-heat) boiler. Gas-Turbine Cogeneration with a heat recovery steam generator boiler (Towler 2012 Fig 3.1) Overall, the process illustrated is not much different from a …Get Price

  • (PDF) Report on "Steam Power Plant" | Saddam Hussain Sohag

    Steam condensing system consists of the following: (a) Condenser (b) Cooling water (c) Cooling tower (d) Hot well (e) Condenser cooling water pump (f) Condensate air extraction pump (g) Air extraction pump (h) Boiler feed pump (i) Make up water pump. 3.1.2 Steam production: Boiler is an apparatus to produce steam.Get Price

  • Railroad Museum of Pennsylvania | Roster

    Prompted by the enormous safety hazards of coal-burning steam locomotives using the new Hudson River Tunnels, the Pennsylvania Railroad developed the first prototype of its new steel passenger cars. a remarkable feat for a freight engine weighing in at 314,000 pounds with a hand-fired boiler. L1's served well until the end of steam on the Get Price

  • Railway Preservation News • View topic - How much can one

    Dec 07, 2021 · Several posts in this thread mentioned that an engine with a small boiler might not be able to meet steam demand going uphill, and would have to work on stored steam. While I grant you this is true, I must qualify that by saying "true of coal burners". The harder you work an oil burner, the better they steam.Get Price