industrial 550 bhp water tube steam boiler

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :industrial 550 bhp water tube steam boiler
  • Supply Capacity : 10 units/month :industrial 550 bhp water tube steam boiler
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

Get display discount

Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Horsepower - Wikipedia

    Boiler horsepower is a boiler's capacity to deliver steam to a steam engine and is not the same unit of power as the 550 ft lb/s definition. One boiler horsepower is equal to the thermal energy rate required to evaporate 34.5 pounds (15.6 kg) of fresh water at 212 °F (100 °C) in one hour.Get Price

  • Basic Power and Industrial Plant Engineering - VSIP.INFO

    Boiler - 13 (ME Bd. Oct. 1986) A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 5%, heating surface area is 0.91 m 2/boiler Up, and the heating value of fuel is 18,400 Kcal/kg. The total coal available in the bunker is 50,000 kg.Get Price

  • Horsepower - Wikipedia

    Boiler horsepower is a boiler's capacity to deliver steam to a steam engine and is not the same unit of power as the 550 ft lb/s definition. One boiler horsepower is equal to the thermal energy rate required to evaporate 34.5 pounds (15.6 kg) of fresh water at 212 °F (100 °C) in one hour.Get Price

  • Basic Power and Industrial Plant Engineering - VSIP.INFO

    Boiler - 13 (ME Bd. Oct. 1986) A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 5%, heating surface area is 0.91 m 2/boiler Up, and the heating value of fuel is 18,400 Kcal/kg. The total coal available in the bunker is 50,000 kg.Get Price

  • Compre Special Project (ppe &ipe) [vnd5gjm03rlx]

    Steam at the rate of 70,000 kg/hr from the boiler drum enters the superheater inlet header at 8.3 Mpa and 485oC. Combustion products at 980oC enters the superheater proper at the rate of 160,000kg/hr. Superheater elements are made of 60 mm O.D. …Get Price

  • Board Exam1 | PDF | Enthalpy | Pressure - Scribd

    6. A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 65%, heating surface area is 0.91 m 2 per Bo. Hp, and the heating value of fuel is 18,400 kCal/kg. The total coal available in the bunker is 50,000 kg. Determine the no. of hours to consume the available fuel.Get Price

  • Watt Calculator - Joules - Watts - Kilowatts - Therms

    Power rating of steam-boliers is in units of BHP (boiler -horsepower) One BHP (Boiler Power)= 33,500 BTU/hr = 9.803 kilowatts (The Boiler-BHP power unit is a bit confusing becasue BHP could be confused with brake-horsepower (b hp ) which is an auto-industry terminology)Get Price

  • Combustion Evaluation: Sources and Control Devices

    In commercial or industrial boiler installations, boilers are rated based on their square feet of heating surface. Packaged boilers today are commonly rated on the basis that 5 sq. ft. of heating surface will produce 1 boiler horsepower, or 33, 500 btu of useful heat, and some claim even less surface required per BHP.Get Price

  • Board Exam1 | PDF | Enthalpy | Pressure - Scribd

    6. A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 65%, heating surface area is 0.91 m 2 per Bo. Hp, and the heating value of fuel is 18,400 kCal/kg. The total coal available in the bunker is 50,000 kg. Determine the no. of hours to consume the available fuel.Get Price

  • Compre Special Project (PPE &IPE) | PDF | Boiler | Thermal

    Exhaust steam at 7 kPa at the rate of 75 kg/s enters a single pass condenser 2. containing 5,780 pcs copper tubes with a total surface area of 2950m . The steam has a moisture content of 10 % and the condense leaves saturated liquid at steam. temperature. The cooling water flow rate is 4,413 liters per second entering at 20 C .Get Price

  • Watt Calculator - Joules - Watts - Kilowatts - Therms

    Power rating of steam-boliers is in units of BHP (boiler -horsepower) One BHP (Boiler Power)= 33,500 BTU/hr = 9.803 kilowatts (The Boiler-BHP power unit is a bit confusing becasue BHP could be confused with brake-horsepower (b hp ) which is an auto-industry terminology)Get Price

  • Compre Special Project (ppe &ipe) [vnd5gjm03rlx]

    Steam at the rate of 70,000 kg/hr from the boiler drum enters the superheater inlet header at 8.3 Mpa and 485oC. Combustion products at 980oC enters the superheater proper at the rate of 160,000kg/hr. Superheater elements are made of 60 mm O.D. …Get Price

  • Compre Special Project (PPE &IPE) | PDF | Boiler | Thermal

    Exhaust steam at 7 kPa at the rate of 75 kg/s enters a single pass condenser 2. containing 5,780 pcs copper tubes with a total surface area of 2950m . The steam has a moisture content of 10 % and the condense leaves saturated liquid at steam. temperature. The cooling water flow rate is 4,413 liters per second entering at 20 C .Get Price

  • Combustion Evaluation: Sources and Control Devices

    In commercial or industrial boiler installations, boilers are rated based on their square feet of heating surface. Packaged boilers today are commonly rated on the basis that 5 sq. ft. of heating surface will produce 1 boiler horsepower, or 33, 500 btu of useful heat, and some claim even less surface required per BHP.Get Price